Microlens quality fluctuates significantly, and yields remain unstable – is the problem in the manufacturing process or in the inspection? Sub‑nanometre inspection reveals many overlooked quality truths.
I. Common Causes of Quality Fluctuation
Quality fluctuations in microlenses are typically not due to a single cause, but a systemic issue resulting from multiple factors compounding together:
Inconsistent grinding and polishing process parameters (pressure, speed, time fluctuations)
Fixture wear or mounting errors
Batch‑to‑batch variations in polishing slurry
Environmental temperature and humidity fluctuations
Incoming silicon wafer consistency variations
These factors intertwine to form a complex causal network. Traditional inspection methods often only show the outcome – "yield has dropped" – but cannot reveal "which specific link in the process is the problem."
II. Why Traditional Inspection Cannot See the Truth
Traditional inspection tools (profilometers, microscopes) have a fundamental limitation: they can only tell you "pass" or "fail," but cannot tell you "where exactly it fails" or "by how much."
This is like using an instrument that only displays "pass/fail" to diagnose a complex machine – you know it's broken, but you don't know which component is faulty.
Sub‑nanometre inspection is fundamentally different – it generates complete 3D topography maps, PV/RMS/Ra values, and surface form error distributions. With laser interferometry non‑scanning imaging technology (such as the MCZX Qiuhao R Series), inspection data can pinpoint exactly which lens and which specific area, enabling traceability back to specific workstations and process steps.
"Invisibility" is the boundary of traditional inspection; "clarity" is where sub‑nanometre inspection begins to deliver value.

III. Quality Patterns Revealed by Sub‑Nanometre Inspection
Through extensive accumulation of full‑inspection data from microlens mass production, sub‑nanometre inspection has revealed the root‑cause distribution patterns of quality issues:
With sub‑nanometre inspection data, quality analysis is no longer guesswork – it becomes data‑driven, precision‑targeted identification.
This also explains why many factories, even when "strictly following process documents," still experience yield fluctuations – because 70% of the issues originate from day‑to‑day variations in tooling and consumables, and traditional inspection simply cannot see the impact of these variations.
IV. Building a Quality Closed Loop with Sub‑Nanometre Full Inspection
The value of sub‑nanometre inspection goes beyond "inspecting" – it enables "controlling." The following is a practical four‑step closed‑loop process:
Step 1: Archive full‑inspection data and establish a quality baseline
PV/RMS/Ra data from every lens is archived, forming batch‑level quality records. This is the foundation for all subsequent analysis.
Step 2: Analyse data to identify high‑frequency defect patterns
Through SPC (Statistical Process Control) analysis, identify the most common defect types and distribution patterns – is edge roll‑off prevalent? Or is centre sagging concentrated?
Step 3: Optimise processes based on defect root causes
Use data to pinpoint specific workstations and processes. For example: edge roll‑off concentrated on a particular polishing machine → check that machine's fixture pressure and slurry flow rate.
Step 4: Continuously monitor and verify improvement effectiveness
After improvement measures are implemented, continue using sub‑nanometre full‑inspection data to verify effectiveness – did the improvement work? How long does the effect last? Are further adjustments needed?
Sub‑nanometre full‑inspection data is the starting point of quality improvement – not the end point.
V. Conclusion
The root cause of microlens quality instability is often not that we can't make them well, but that we can't see the problems.
When traditional inspection can only provide a binary "pass/fail" judgment, engineers are essentially working in the dark – they know there is a problem, but they don't know where it is.
The MCZX Qiuhao R Series (laser interferometric 3D profilometer / laser interferometric 3D topography measurement instrument), with 0.5 nm vertical resolution + ~1‑second per lens inspection speed, upgrades microlens quality control from "blind men touching an elephant" to "data‑driven navigation." When every lens's complete topography data is recorded, analysed, and fed back to the process side, "quality instability" is no longer an unsolvable problem.

- Share
-
12
- What Does Sub‑Nanometre Accuracy Mean? What Can 0.5 nm See in Silicon Lens Inspection?
- Why Are Silicon Photonics Wafers Suddenly So Popular? How Have Inspection Requirements Changed?