Affiliation: Shenzhen Qianhai Yuzhuo (Apex) — Authorized Distributor of PILLAR Corporation
Meta description: PILLAR (Japan) conductive (anti-static) CTC sleeves slip over PFA tubing to provide electrostatic shielding and prevent spark-discharge fires. Fits Ø6–Ø25 / 1/4"–1" tubing, ambient to 85 °C, volume resistivity 5.0×10² Ω·cm, with high visibility and quick dedicated-tool installation. For semiconductor/LCD high-purity flammable chemical lines. Authorized distributor: Shenzhen Qianhai Yuzhuo (Apex).
Models: Conductive (anti-static) sleeve CTC-05 / CTC-08 / CTC-20 (with dedicated tool CTC-XX-TOOL-A)
Conductive anti-static CTC sleeve product appearance — static-shielding cover over PFA tubing
Core Value
PILLAR conductive (anti-static) sleeve CTC — electrostatic shielding over PFA tubing to prevent spark-discharge fires.
· Effective electrostatic shielding: slipped over PFA tubing, it prevents sparks through electrostatic shielding and stops fires caused by static discharge.
· Cost-effective: made of conductive polypropylene (conductive PP) resin for economical cost.
· High visibility: the sleeve's unique design lets you directly observe the fluid flow inside the resin tube.
· Easy operation: with a dedicated tool, it can be slid on quickly after piping is completed.
· Wide tube range: covers Ø6–Ø25 and 1/4"–1", the full range of common PFA tubing.
· Compliant design: designed in line with the Japan National Institute of Occupational Safety and Health "Guideline for Static Electricity Safety - 2007 (TR-No.42)".
Product Description
The conductive (anti-static) tube cover is a companion product PILLAR offers for static protection of high-purity PFA piping. PFA tubing itself is an insulator; when delivering low-conductivity chemicals, static easily builds up on the tube wall. Slipping a conductive sleeve over the tube provides electrostatic shielding that drains surface static, preventing ignition by spark discharge.
1. Operating Principle and Technical Breakthrough
The sleeve is made of conductive polypropylene. Slipped over the PFA tube and grounded, it forms an electrostatic shielding layer that conducts away static accumulated on the PFA tube's outer surface, preventing spark discharge. Its unique slotted/transparent design keeps the inner PFA tube and fluid visible, balancing static protection with operational visibility.
2. Performance and Precision Parameters
· Material: conductive polypropylene.
· Applicable tube OD: Ø6–Ø25, 1/4"–1" (corresponding to CTC-05/08/20).
· Operating temperature: ambient to 85 °C.
· Volume resistivity: 5.0×10² Ω·cm (measured at 1 m).
· Surface charged potential: 0.11–1.14 kV.
· Sold unit: 20 m/roll; installed with a dedicated tool.
Conductive anti-static sleeves in different tube-size ranges
3. Materials and Product Applicability
· Model correspondence: CTC-05 (fits 6×4 / 1/4" series), CTC-08 (fits 8×6 / 3/8" series), CTC-20 (fits 10×8 to 25×22 / 1/2" to 1" series).
· Dedicated tools: CTC-05-TOOL-A, CTC-08-TOOL-A, CTC-20-TOOL-A.
· Applicable scenarios: PFA lines delivering flammable/explosive or low-conductivity high-purity chemicals in semiconductor/LCD and similar plants.
· Boundary note: it only prevents static on the outer PFA tube surface; it cannot prevent internal static generated by fluid rubbing against the inner wall. The sleeve must be grounded in use.
4. Core Value and Application Benefits
· Fire safety: shields surface static sparks, lowering fire risk on flammable/explosive chemical lines.
· No impact on piping: slips over the outside without changing the original flow path or fittings; can be added after piping is complete.
· Easy O&M: visibility lets operators directly observe fluid flow; the dedicated tool enables quick installation and reduces labor.
Dedicated installation tool for the anti-static sleeve
Key Advantages
(1) Electrostatic Shielding + Visibility + Easy Installation in One
· Effective shielding: the conductive PP sleeve shields outer-surface static to prevent spark discharge.
· High visibility: the unique design lets you observe fluid inside the resin tube, aiding flow and blockage checks.
· Easy operation: with the dedicated tool it can be slid quickly along the tube after piping is complete.
(2) Cost-Effective Conductive Material
Conductive polypropylene resin delivers electrostatic shielding at an economical cost. Product characteristic values are measured reference values (volume resistivity 5.0×10² Ω·cm, surface potential 0.11–1.14 kV).
(3) Three-Step Specified Installation
Slip the dedicated tool onto the PFA tube;
Fit the sleeve onto the front end of the dedicated tool;
Slide the dedicated tool along the tube to complete the covering.

Anti-static sleeve installation step 1 — dedicated tool fitted onto the PFA tube
Technical Specifications
Item | Parameter |
Product name | Conductive (anti-static) tube cover |
Material | Conductive polypropylene |
Applicable tube OD | Ø6–Ø25, 1/4"–1" |
Models | CTC-05 / CTC-08 / CTC-20 |
Dedicated tools | CTC-05-TOOL-A / CTC-08-TOOL-A / CTC-20-TOOL-A |
Operating temperature | Ambient to 85 °C |
Volume resistivity | 5.0×10² Ω·cm (measured at 1 m) |
Surface charged potential | 0.11–1.14 kV |
Sold unit | 20 m |
Design basis | Japan National Institute of Occupational Safety and Health, "Guideline for Static Electricity Safety - 2007 (TR-No.42)" |
Warranty | 1 year after delivery (degradation from chemical vapor/chemical adhesion/UV is excluded) |
Note: product characteristic values are measured reference values, not guaranteed values; selection should be reviewed in detail against operating conditions.
Applications
Semiconductor Fabs
· Outer static protection for PFA lines delivering low-conductivity/flammable high-purity chemicals.
· Anti-static covering of PFA piping inside delivery stations and chemical cabinets.
LCD / OLED and Photovoltaics
· Spark-discharge prevention for high-purity chemical lines in panel and photovoltaic processes.
· Piping in clean rooms with high explosion/fire-prevention requirements.
Chemical and Pharmaceutical
· Outer-surface electrostatic shielding for low-conductivity chemical delivery lines.
· Chemical distribution systems with spark-prevention requirements.
FAQ
Q: What should I watch for when using the conductive anti-static sleeve?
A: The sleeve slips over the PFA tube and prevents outer-surface static sparks through shielding; it must be grounded in use. It only prevents static on the tube's outer surface and cannot prevent internal static generated by fluid rubbing the inner wall. Operating temperature is ambient to 85 °C; install it with the dedicated tool by sliding it on after piping is complete.
Q: Which tube sizes does the sleeve fit? How do I select?
A: It covers Ø6–Ø25 and 1/4"–1" across three models — CTC-05/08/20 — each with a matching dedicated tool CTC-XX-TOOL-A. Select the model by PFA tube OD; sold length is 20 m per roll.
Q: Does the sleeve block the view of the line?
A: No. The unique sleeve design is visible, so you can directly observe fluid flow inside the resin tube to judge operating status and blockages.
Q: What are the warranty and usage boundaries?
A: Warranty is 1 year after delivery; material degradation from chemical vapor, chemical adhesion or UV is excluded. Use outside specifications, external-equipment factors, modification, or force majeure are not covered. This product protects outer-surface static only; internal fluid-friction static must be assessed separately.
Q: How does it compare with whole-tubing anti-static solutions?
A: CTC is a low-cost retrofit that slips over existing PFA tubing with the dedicated tool, without changing the flow path or fittings, and keeps the line visible. It is best for outer-surface spark prevention on flammable chemical lines; for internal fluid static, pair it with PILLAR's conductive/anti-static tubing or grounded delivery-system measures.
Shenzhen Qianhai Yuzhuo (Apex) — Authorized Distributor of PILLAR Corporation
WeChat: qhyz1303 / Tel: +86-755-26609876 / Email: qhyz@apexe.net / Web: http://www.apexe.net/